Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 79 Next »

General Function Checklist

Download and unzip test genomes.zip 

The folder "test genomes" should contain the following files:

  • E_unicornis_Jul_2043.bed.gz.tbi
  • E_unicornis_Jul_2043.bed.gz
  • E_unicornis_Jul_2043.2bit
  • T_rex_Jun_1993.2bit

Start IGB 9.1.8 or later.
Select the Plug-ins tab.
Click Launch App Manager.
In the IGB App Manager window:

Select Manage Repositories...

In the Preferences window App Repositories tab:

Click Add...

In the Add Plugin Repository window enter the following information:

  • Name: Quickload Saver Repo

Click Submit

In the Preferences window App Repositories tab:
Click Done

In the IGB App Manager window:
Select the Quickload Saver app.
Click Install.

Checkpoint:

  • mac
  • linux
  • windows

Close the IGB App Manager window.
In IGB:
Select File > Open Genome from File...

In the Open Genome from File window:

  • Reference Sequence: Click Choose File... and select E_unicornis_Jul_2043.2bit
  • Genus: Equus
  • Species: unicornis
  • Variety: (leave blank)
  • Genome release date: July 2043

Click OK

Select File > Open File...
Select E_unicornis_Jul_2043.bed.gz
Click Open
In the Data Access tab in the Data Management Table section:
Change the Load Mode to Genome for E_unicornis_Jul_2043.bed.gz
Change the color of the foreground (FG) to red


Select File > Save Custom Genome to Local Quickload Site
Select your desktop as the destination and unicorn as the name.
Click Save

In IGB:
Select File > Open Genome from File...

In the Open Genome from File window:

  • Reference Sequence: Click Choose File... and select the T_rex_Jun_1993.2bit
  • Genus: Tyrannosaurus 
  • Species: rex
  • Variety: (leave blank)
  • Genome release date: June 1993

Click OK

Select File > Open URL...
In the Open URL window:
Enter URL: http://igbquickload.org/quickload/S_cerevisiae_Apr_2011/S_cerevisiae_Apr_2011_ncbiRefSeq.bed.gz


Click OK
In IGB:
In the Data Access tab in the Data Management Table section:
Change the Load Mode to Genome for S_cerevisiae_Apr_2011_ncbiRefSeq.bed.gz
Change the color of the foreground (FG) to green.


Select File > Save Custom Genome to Local Quickload Site
Select your desktop as the destination and rex as the name.

In IGB:

Select File > Preferences...

In the Preferences window select the Other Options tab.

Click Reset Preference to Defaults and then click Yes

Open IGB
In IGB:
Select File > Preferences
In the Preferences window:
Select the Data Sources tab.
In the Data Sources tab:
Click Add...
In the Add Data Source window:

  • Name: unicorn
  • Type: Quickload
  • Click Choose local folder

Select the unicorn folder on your desktop and click Open

Click Submit


In the Data Sources tab:
Click Add...
In the Add Data Source window:

  • Name: rex
  • Type: Quickload
  • Click Choose local folder

Select the rex folder on your desktop and click Open

In the Add Data Source tab:
Click Submit

Checkpoint:

  • mac
  • linux
  • windows


Close the Preferences window
In IGB:
Select the Log tab and click Clear
In the Species dropdown select Equus unicornis
In the Genome Version dropdown select E_unicornis_Jul_2043
In the Data Access tab, E_unicornis_Jul_2043.bed.gz should be set to Load Mode Genome and should be red (FG)

Compare your IGB to the picture below and check the box if they appear to be the same:

  • mac
  • linux
  • windows


Navigate to chrXVI:2,618-2,661
Click Load Sequence

Compare your IGB to the picture below and check the box if they appear to be the same:

  • mac
  • linux
  • windows


Select the Log tab and check for errors.

No errors in Log tab:

  • mac
  • linux
  • windows

Click Clear in the Log tab if there are no errors.

In the Species dropdown select Tyrannosaurus rex
In the Genome Version dropdown select T_rex_Jun_1993
In the Data Access tab, S_cerevisiae_Apr_2011_ncbiRefSeq.bed.gz should be set to Load Mode Genome and should be green (FG).

Compare your IGB to the picture below and check the box if they appear to be the same:

  • mac
  • linux
  • windows


Navigate to chrXVI:2,618-2,661
Click Load Sequence

Compare your IGB to the picture below and check the box if they appear to be the same:

  • mac
  • linux
  • windows


Select the Log tab and check for errors.
Click Clear in the Log tab if there are no errors.

No errors in Log tab:

  • mac
  • linux
  • windows



  • No labels